Summary
Dell Secure Connect Gateway (SCG) Virtual Edition versions prior to 5.36.00.16 contain an out-of-bounds write vulnerability (CWE-787). Impact may include application instability, denial of service, disclosure of sensitive information, arbitrary memory modification and potentially execution of attacker-controlled code within the affected process.
Per the CVSS vector (8.4, high), the attack requires local access to the system. No authentication or user interaction is needed and attack complexity is low. Successful exploitation has a high impact on confidentiality, integrity and availability.
The vulnerability is not currently listed in the CISA KEV catalog, and no EPSS data is available.
Who is affected
Organizations running Dell Secure Connect Gateway Virtual Edition versions earlier than 5.36.00.16.
What to do
- Update Dell Secure Connect Gateway Virtual Edition to version 5.36.00.16 or later.
- Review Dell security advisory DSA-2026-386 (KB 000503504) for details on this and the other listed vulnerabilities.
- Check your inventory to identify SCG Virtual Edition instances running versions earlier than 5.36.00.16.
- Until updated, restrict local and shell access to SCG appliances to authorized administrators only.
Affected products and versions
CVSS vector, explained
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Attack vector
- Local
- Attack complexity
- Low
- Privileges required
- None (no login)
- User interaction
- Not required
- Scope
- Vulnerable component only
- Confidentiality
- High impact
- Integrity
- High impact
- Availability
- High impact
Weakness type (CWE)
- CWE-787 Out-of-bounds Write
References
- www.dell.com/support/kbdoc/en-us/000503504/dsa-2026-386-security-update-for-dell-secure-co vendor advisory