Incident response on call, 24/7: +385 98 1900 984NewIR Retainer: a team on contract before an attack
HR · EN
Critical 9.4CVE-2026-97180

Command Injection in ASSA ABLOY Seawing SC-1000 WebConfig

Published 25/11/2026 · Updated 25/11/2026 · ASSA ABLOY Seawing SC-1000 WebConfig

Original description

ASSA ABLOY Seawing SC-1000 WebConfig is vulnerable to remote command injection via HTTP request. Due to the lack of input sanitization, a privileged attacker can inject shell metacharacters in the server parameter, resulting in arbitrary command execution as the root user on the operating system. This issue was fixed in version 1.5.14.

Affected products and versions

ASSA ABLOY Seawing SC-1000 WebConfig< 1.5.14Fixed in: 1.5.14

CVSS vector, explained

CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Attack vector
Network (from the internet)
Attack complexity
Low
Attack requirements
None
Privileges required
Administrator
User interaction
Not required
Confidentiality
High impact
Integrity
High impact
Availability
High impact

Weakness type (CWE)

  • CWE-78 Improper neutralization of special elements used in an OS command ('OS command injection')