Dežurni tim za incidente, 0–24: +385 98 1900 984NovoIR Retainer: tim ugovoren prije napada
HR · EN
Visoka 7.8CVE-2026-50048

Genetec Security Center

Objavljeno 24. 11. 2026. · Ažurirano 25. 11. 2026. · Genetec Security Center

Izvorni opis (engleski)

Za ovu ranjivost još nema našeg sažetka. Prikazujemo službeni opis proizvođača.

Genetec Security Center can expose access control unit credentials in plain text in server log files when specific non-default logging options are enabled. An attacker with local access to the affected log files could retrieve and use these credentials.

Rješenje proizvođača

Upgrade to Security Center 5.10.4.32, 5.11.3.30, 5.12.2.20, 5.13.3.8, 5.14.0.1, or any later version. Customers using an unsupported release should upgrade to a supported version.

Privremena mjera proizvođača

Use the default logging configuration whenever possible. If additional diagnostic logging is required for troubleshooting, limit its use, restrict access to the resulting log files, and securely delete those files when they are no longer required.

Izvorni tekst iz CVE zapisa proizvođača.

Zahvaćeni proizvodi i verzije

Genetec Inc. Genetec Security Center

CVSS vektor, objašnjeno

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Put napada
Lokalno, na sustavu
Složenost napada
Niska
Potrebne ovlasti
Obični korisnik
Interakcija korisnika
Nije potrebna
Opseg
Samo ranjiva komponenta
Povjerljivost
Visok utjecaj
Integritet
Visok utjecaj
Dostupnost
Visok utjecaj

Vrsta slabosti (CWE)

  • CWE-532 Insertion of Sensitive Information into Log File

Reference